Defining Foundation or Structural Failure

Featured Article

When has a foundation or any other structural unit failed? There are three categories in which a structure could be placed with regard to structural performance:

  1. Obvious failure:
    • Collapse
    • Major distress and distortion
    • Functionality Impairment
  2. Obvious non-failure:
    • No distress
    • No distortion
  3. Not so obvious:
    • Some distress
    • Some distortion
    • Partial functionality impairment

Case I and case II above are clear cut, but case III requires criteria to determine which camp it would fall into. Therefore, we need foundation and structural performance criteria. Experience has shown the following differential movement to produce the distress indicated. The ratios indicated are “differential ratios” and are defined as vertical movement divided by horizontal distance over which it occurs.

  1. Sheet rock cracking, any wall – 1/480.
    Sheet rock cracking – ceiling 1/360
  2. Masonry cracking – Eight foot wall will show cracking at 1/600 to 1/800.

Design standards – Typical foundation design procedures such as the B.R.A.B. #33 Report or the Post Tensioning Institute Design Manual, plus numerous other structural codes and criteria for various structural elements, call for designs permitting maximum movements ranging from deflection ratios of 1/360 to 1/800 for foundation flatness. For example, a deflection ratio of 1/360 translates to 1 inch in 30 feet. A question which is often of considerable interest is whether the observed out of levelness is due to movement since construction or is due to construction finishes.

Simply observing cracks in concrete or timber is not necessarily enough to indicate structural failure. Such cracking must be accompanied by distress in walls, ceilings, etc. or functionality loss or have excessive deformation exceeding some of the previously listed criteria. It should be noted that not all masonry or sheet rock cracking is due to structural movement. It could be drying shrinkage or thermal stress. Conversely, excessive deformation without cracking of the structural members can also create an effective failure in the super-structure.

Loss of functionality includes sticking doors or windows due to frame movement, inability to latch doors or accessible building envelope openings.

In conclusion, foundation or structural failures depend on the character of the structure and its use. Most residences and small commercial buildings can be considered in a failure mode if the foundation deformation exceeds 1/360. However, not all structures will indicate distress at this amount of movement, depending on the brittleness and character of the walls, both interior and exterior.

Explore

MLAW Engineers, Structural Engineering, Austin, San Antonio, Houston, Dallas, Temple, Waco, Killeen, Bryan, College Station

Geological Faults and Foundation Design

By Staff Editor | March 17, 2022

Austin and Central Texas abounds with geologic faults, the most prominent of which is the Balcones Fault, or “fault system”. These faults are especially common in a band, which runs north and south through Austin and similar areas in Georgetown, Round Rock, Buda, Kyle, San Marcos, New Braunfels and parts of San Antonio. The band…

Read More
MLAW Engineers, Structural Engineering, Austin, San Antonio, Houston, Dallas, Temple, Waco, Killeen, Bryan, College Station

When Should You Stress a Cable Slab?

By Staff Editor | March 17, 2022

The question as to when the proper time to apply the stressing force to the post tensioned cable in this type of reinforced foundation is of considerable interest. If you apply the stressing load too soon you have the danger of pulling cable anchorages out of the green concrete. If you wait too long there…

Read More

Staff Editor

MLAW Engineers is recognized as one of the most respected structural engineering firms in Texas. Over 54 years of superior engineering by MLAW Engineers can be seen in over 400,000 completed projects nationwide.

Leave a Comment