Defining Foundation or Structural Failure

Featured Article

When has a foundation or any other structural unit failed? There are three categories in which a structure could be placed with regard to structural performance:

  1. Obvious failure:
    • Collapse
    • Major distress and distortion
    • Functionality Impairment
  2. Obvious non-failure:
    • No distress
    • No distortion
  3. Not so obvious:
    • Some distress
    • Some distortion
    • Partial functionality impairment

Case I and case II above are clear cut, but case III requires criteria to determine which camp it would fall into. Therefore, we need foundation and structural performance criteria. Experience has shown the following differential movement to produce the distress indicated. The ratios indicated are “differential ratios” and are defined as vertical movement divided by horizontal distance over which it occurs.

  1. Sheet rock cracking, any wall – 1/480.
    Sheet rock cracking – ceiling 1/360
  2. Masonry cracking – Eight foot wall will show cracking at 1/600 to 1/800.

Design standards – Typical foundation design procedures such as the B.R.A.B. #33 Report or the Post Tensioning Institute Design Manual, plus numerous other structural codes and criteria for various structural elements, call for designs permitting maximum movements ranging from deflection ratios of 1/360 to 1/800 for foundation flatness. For example, a deflection ratio of 1/360 translates to 1 inch in 30 feet. A question which is often of considerable interest is whether the observed out of levelness is due to movement since construction or is due to construction finishes.

Simply observing cracks in concrete or timber is not necessarily enough to indicate structural failure. Such cracking must be accompanied by distress in walls, ceilings, etc. or functionality loss or have excessive deformation exceeding some of the previously listed criteria. It should be noted that not all masonry or sheet rock cracking is due to structural movement. It could be drying shrinkage or thermal stress. Conversely, excessive deformation without cracking of the structural members can also create an effective failure in the super-structure.

Loss of functionality includes sticking doors or windows due to frame movement, inability to latch doors or accessible building envelope openings.

In conclusion, foundation or structural failures depend on the character of the structure and its use. Most residences and small commercial buildings can be considered in a failure mode if the foundation deformation exceeds 1/360. However, not all structures will indicate distress at this amount of movement, depending on the brittleness and character of the walls, both interior and exterior.

Explore

MLAW Engineers - Structural Engineers examines the topic of central Texas geology

The Geology of Central Texas, or Why Foundations Do Funny Things

By Staff Editor | October 16, 2023

Introduction Central Texas has one of the most geologically diverse small regions to be found anywhere in the world. The many geologic layers, folds and faults cause different types of soil to outcrop in great profusion in this region. Many people have heard of the Balcones Fault. This is a system of many faults that…

Read More
MLAW Engineers - Structural Engineers examines the topic of cracks in concrete.

Cracks! In Concrete

By Staff Editor | October 16, 2023

One of the more disagreeable features of construction concrete is its ability to generate cracks. Cracks are of several varieties. Some are very fine, almost invisible to the naked eye, some are large and ominous looking. There are two basic types of cracks; the first type is shrinkage related while the second type is external…

Read More

Staff Editor

MLAW Engineers is recognized as one of the most respected structural engineering firms in Texas. Over 54 years of superior engineering by MLAW Engineers can be seen in over 400,000 completed projects nationwide.

Leave a Comment